FCC Part 15.407有传导杂散的要求吗
先说结论:FCC Part 15.407没有传导杂散的要求。
以下从技术规范、测试方法及行业误读背景三个方面进行专业分析:
法规技术条款解析
(b) Undesirable emission limits. Except as shown in paragraph (b)(10) of this section, the maximum emissions outside of the frequency bands of operation shall be attenuated in accordance with the following limits:
(1) For transmitters operating in the 5.15-5.25 GHz band: All emissions outside of the 5.15-5.35 GHz band shall not exceed an e.i.r.p. of −27 dBm/MHz.
(2) For transmitters operating in the 5.25-5.35 GHz band: All emissions outside of the 5.15-5.35 GHz band shall not exceed an e.i.r.p. of −27 dBm/MHz.
(3) For transmitters operating in the 5.47-5.725 GHz band: All emissions outside of the 5.47-5.725 GHz band shall not exceed an e.i.r.p. of −27 dBm/MHz.
......
- 限值特性:
条款明确要求频段外 emission 需满足 e.i.r.p.(等效全向辐射功率)限值(例如−27 dBm/MHz),而非传导功率限值。
- 测试方法指向性:
法规未规定从射频端口直接测量传导杂散,而是通过辐射评估合规性。此要求与FCC Part 15.205对限制频段(Restricted Bands)的辐射限值(峰值74 dBμV/m、均值54 dBμV/m)形成互补,但二者均属辐射范畴。
测试方法的合规性依据
ANSI C63.10标准:
如该标准第12.7.4.2节所述,允许采用 天线端口传导测试(Antenna port conducted measurements) 作为辐射杂散测量的替代方法,但需通过换算补偿天线增益及相关因子以模拟辐射场强。此方法仅为辐射测试的等效替代方案,而非独立针对传导杂散的要求。
术语区分:
- 传导杂散(Conducted Spurious Emissions) :直接测量射频端口的杂散发射,限值基于端口功率(如dBm)。
- 传导法测辐射杂散(Conducted Method for Radiated Spurious Emissions) :通过端口测量推导辐射场强,需换算为e.i.r.p.。 Part 15.407仅涉及后者情形,且其本质仍属辐射合规性验证。

题外话
为什么现在很多人会误以为 15.407有传导杂散的要求呢,这可能是一个很长的故事。故事的开始,应该要追溯到2022年TCBC发布的文件

这个文件的发布,导致TCB只能强行要求实验室提供band edge的测试图。但如果使用辐射法测试,无疑会对实验室造成很大压力,所以TCB想了个办法,提供一张传导法测试的边带图片,睁一只眼闭一只眼也就过去了。
TCB的原意可能是想让实验室参考 ANSI C63.10 Section 12.7.4.2 用现在可接受的传导法作为一种替代法来执行辐射杂散的测试,但是随着时间的推移,渐渐被误传为传导杂散的要求了。